•VISUALLY INSPECT PRIMARY CONTROL POINTS FOR SIGNS OF DETERIORATION AND OVERHEATING
•PERFORM THERMAL IMAGING SURVEYS USING PRECISE THERMOGRAPHY EQUIPMENT.
•CHECK FOR SIGNS OF PERSISTENT OVERHEATING AND SINGLE OUT SPECIFIC AREAS FOR REPAIR OR PART REPLACEMENT.
•CHECK PHASE BALANCING AND RECOMMEND SOLUTIONS IF REQUIRED
• INSPECT MOTOR CONTROL CIRCUITS AND CHECK FOR APPROPRIATE OVERCURRENT PROTECTION.
•CONFIRM THAT INDICATORS, SENSORS, AND WARNING LIGHTS ARE FUNCTIONING CORRECTLY.
• VERIFY THAT GROUND-FAULT AND FEEDER SHORT-CIRCUIT PROTECTION IS SIZED AND OPERATING ACCORDING TO THE SPECIFIC APPLICATION.
•CHECK ALL POWER METERS FOR REGULAR FUNCTION
•TORQUE TEST AND INSPECT BOLTED ELECTRICAL CONNECTIONS TO SPECIFIED LEVELS WHENEVER NEEDED.
•PROVIDE A DETAILED REPORT POST EVERY INSPECTION AND A BOLT-ON COC IF REQUIRED.
•CHECK CABLE ASSEMBLIES AND OTHER WIRING METHODS IN ROOMS, HALLWAYS, STAIRWAYS, AND CEILINGS.
•CHECK CABLE INSTALLATIONS AND CIRCUIT BOXES FOR GENERAL SUITABILITY.
•EXAMINE BOXES FOR WARNING LIGHTS AND OTHER IRREGULARITIES.
•ENSURE EQUIPMENT GROUNDING CONDUCTORS ARE SPECIFIED CORRECTLY
•EXAMINE LIGHTING OUTLETS AND ENSURE THEY ARE PROPERLY WIRED ON GENERAL LIGHTING CIRCUITS.
•SURVEY RELEVANT RECEPTACLE OUTLETS FOR BRANCH CIRCUIT TYPE
•IDENTIFY AND REPAIR FRAYED WIRES CLOSE TO WATER OUTLETS IN BATHROOMS.
•LOOK FOR IRREGULAR WIRING ARRANGEMENTS AND LIGHTING OUTLETS ON WALLS.
•CHECK THE GROUNDING ELECTRODE CONDUCTOR CONNECTIONS AND BURIED CONNECTIONS CONDUCTIVITY AND SUITABILITY.
•EXAMINE AND REPAIR ELECTRICAL SURGE PROTECTION UNITS (WHERE INSTALLED).
•INSPECT TIMERS, POWER SUPPLY UNITS, RELAYS, AND CONTROL WIRING FOR HUMIDITY OR TEMPERATURE DAMAGE, AS WELL AS REGULAR WEAR.
•DETECT SIGNS OF ELECTRICAL DISTURBANCE AS AN INDICATOR OF MINOR SHORTS AND SPARKING.
•ENSURE PROPER VOLTAGE IN ALL ROOMS AND AREAS OF MAJORITY ELECTRICAL USAGE
•PERFORM THERMAL IMAGING SURVEYS USING PRECISE THERMOGRAPHY EQUIPMENT OF ALL DISTRIBUTION BOARDS
•PROVIDE A DETAILED REPORT POST EVERY INSPECTION AND A BOLT-ON COC IF REQUIRED.
WE MEASURE AND OPTIMISE THE CURRENT PERFORMANCE AND EFFICIENCY OF YOUR INSTALLATION BY:
•MEASURING SOLAR IRRADIANCE, AMBIENT AND PV MODULE TEMPERATURE, ARRAY ORIENTATION AND TILT ANGLES.
•ASSESS AND RECOMMEND INSTALLATION IMPROVEMENTS FOR OPTIMAL EFFICIENCY
•JUNCTION BOX AND CABLE EXAMINATION
•OPEN-CIRCUIT VOLTAGE (VOC) TEST:
•SHORT-CIRCUIT CURRENT (ISC) TEST:
•INVERTER MAINTENANCE .
•PANEL: CLEANING
•PROVIDE A DETAILED REPORT POST EVERY INSPECTION AND A BOLT-ON COC IF REQUIRED.